Skip to content

Service and oil treatment companies

Your client hears ‘treat the oil’ from the company that sells the treatment

Your recommendation, backed by an independent, clause-cited reading.

What you get

  • An Asset Health Report for each transformerverification code and QR
  • Readings comparable across laboratoriesone method, one scale
  • Suggested planning windows and technical referencesyour service, scheduled
  • Start with one clienta light agreement
How it works

Put a reading next to your proposal that names the standard, the edition and the clause, in a report your client can check with a code. RONIN works from the oil reports your client already receives: nothing to install, and a light agreement to start with one client.

Asset Health Report, exampleDemo data. Example shown for illustration

Asset Health Report17 Jun 2026

GSU4 330MVA, 400 kV, mineral oil

37.2 ± 6.6Poorsigned by the model

DGA Status 3, IEEE C57.104-2019

Within 30 days, due 17 Jul 2026

  • Increase surveillanceIEEE C57.104-2019 6.1.2.3
  • Investigate the Status 3 readingIEEE C57.104-2019 6.1.2.3
  • Confirm the thermal faultCIGRE TB 962
  • Test whether the oil can be treatedIEC 60422:2024 14.4.1

Next outage

  • Bushings, electrical testsat the next outage

Scan to check this is the document issued.

Testing laboratories

Your client needs to know which transformer to examine first

Your laboratory measures the oil sample. RONIN assesses the transformer’s condition from the laboratory results.

What you get

  • Your report read as it isPDF, spreadsheet or scan
  • Doubts shown to you before any calculationyou confirm the values
  • A reasoned report for your clientstandard, edition, clause
  • A report anyone can checkverification code
How it works

A competent reader can use the assessment and its technical references to plan sampling, inspections and maintenance. Missing measurements can limit the assessment.

Example lab reportDemo data. Example shown for illustration

17 values read, 1 doubt for you, 1 missing

  • H2120ppm
  • CH4250ppm
  • C2H694ppm
  • C2H4800ppm
  • C2H22ppm
  • CO365ppm
  • CO23540ppm
  • Water23ppm
  • Acidity0.22
  • Breakdown voltage42kV
  • Interfacial tension22
  • Tan delta0.024
  • 2-FALnot ordered
  • Tan delta: the sheet reports it in %. Confirm the unit before calculation.
  • 2-FAL: not ordered. The plan adds a furan analysis to the next sample.

Returned: index 37.2 ± 6.6, Poor, signed by the model. DGA Status 3, IEEE C57.104-2019. Four actions within 30 days, each with its clause.

Licensing and integration

You need to inspect the method before you put your name next to it

Review the applicable technical references. Massimiliano Vurro owns the proprietary RONIN algorithms.

What you get

  • Methods and references for the assessmentthe reasoning is visible
  • Founder-owned technology and IPone accountable owner
  • Registered software, 2019Italian public software registry
  • A registered European trademarkSeetalabs
  • Integration and white-label termsagreed case by case
How it works

For transformer manufacturers, monitoring vendors and asset-management platforms. The reasoning behind each number is visible; the technology and its IP are founder-owned; RONIN software is registered in the Italian public software registry since 2019 and Seetalabs is a registered European trademark. Integration and white-label terms are agreed case by case.

What a partner builds on
  • Readings by methodstandard, edition, clause
  • Oil and paper, property by propertyby fluid
  • A health index with its signaturemodel or standards
  • A plan by windowtechnical references for planning
  • Reports anyone can checkcode and QR
  • RONIN ExpertIn development

Strategic conversations

Larger conversations about the technology and its IP are welcome

Write to the founder directly. Every request is read in person.