What are my PCB duties and deadlines?

Screen an equipment inventory, one row per unit, against the Stockholm Convention, the EU profile or US 40 CFR 761: class, obligations, deadlines and action.

It runs in your browser: nothing you enter leaves your device, and no account is needed.

PCB Compliance TriageFree · v1.0.3

What goes in

  • An inventory: one row per unit with its PCB evidence
  • The jurisdiction

Standards

  • Stockholm Convention · Directive 96/59/EC and Regulation (EU) 2019/1021 · 40 CFR 761

What comes out

  • The class and the duties per unit
  • Deadlines and the next action
  • What evidence a classification still needs

PCB Compliance Triage

Enter your values

Accept the tool's conditions inside the frame, then type or paste your values. The result appears in the same frame.

After the result

Email me a copy of this result

The copy is the result shown in the frame, sent once to your address with the tool name and version. Seetalabs keeps no copy of your values.

How it is calculated

Method, standards and worked examples

Every result names the method and the edition it rests on. The detail is here, section by section.

How it works, step by step
  1. Choose the country of the site. The country sets the rules: the 27 EU member States get the EU profile, the United States gets 40 CFR 761, and the other Parties to the Stockholm Convention get the Convention base. For a country that has not ratified the Convention, the Convention rules are shown as an international reference, with a notice that only national law applies. You can change the rules by hand.
  2. Add one row per unit. Tag, equipment type, PCB result in mg/kg, lab method, liquid quantity in litres or kg, and status (in service, stored for reuse, or waste) are enough. Details such as year of manufacture, liquid type, sealed tank or the date of a previous retrofill refine the result when you have them.
  3. Read the dossier. A live summary counts the units by class, the units past a deadline, the estimated kilograms of PCB in the inventory and the next dated deadline. For each unit the dossier gives the class, the duties, the deadlines (marked overdue when already past), an action and a route: retrofill with reclassification where it is allowed, otherwise disposal. Each rule shows the article or section it comes from.

You can print the dossier or save it as PDF. Seetalabs® keeps nothing: to continue later, save the inventory to a file on your computer and open it next time.

Method and standards

The tool applies three sets of rules, each as written in its source text:

  • Stockholm Convention, Annex A Part II (text as of 2025), with the Basel Convention technical guidelines for PCB wastes. Equipment is sorted into the Annex A priorities: above 10 % PCB and above 5 L, above 0.05 % (500 mg/kg) and above 5 L, above 0.005 % (50 mg/kg) and above 0.05 L. The Convention sets 2025 for ending the use of PCB equipment and 2028 for the environmentally sound management of PCB liquids and equipment.
  • European Union: Directive 96/59/EC and Regulation (EU) 2019/1021 Annex I and Article 7, read on the consolidated text of 1 January 2026, where the PCB entries are unchanged.
  • United States: 40 CFR Part 761, edition of 1 July 2024, with the classes PCB Transformer (500 ppm or more), PCB-Contaminated Electrical Equipment (50 to 499 ppm) and non-PCB, and the presumptions of 761.2 for equipment that was never tested.

Thresholds are applied to the letter. The Stockholm Convention and the EU Directive say "more than" 50 and 500 mg/kg, so 50 and 500 are excluded. The Basel waste entry, the EU waste limit and 40 CFR 761 say "or more", so 50 and 500 are included. The same unit at exactly 50 mg/kg can therefore fall on different sides of the line in different texts, and the tool shows it.

Lab results are checked before they are classified. The thresholds refer to total PCB. Total PCB by IEC 61619:1997, EN 12766-2:2001 Method A or gas chromatography by Aroclor is used as reported. EN 12766-2 Method B (five times the sum of six congeners, clause 4.2.1) is used as an estimate in the Stockholm and EU profiles and is not classified under 40 CFR 761. A sum of other congeners, such as the EU-7 set, is not total PCB and is not classified. When a result lies within the reproducibility of the method from the 50, 500 or 100 000 mg/kg thresholds (R = 2 + 0.25 x for IEC 61619 and Method A), the tool asks to repeat the analysis before deciding.

Retrofill estimate. For a transformer in good condition the tool estimates the PCB content after one retrofill cycle as 10 % of the initial content, the return from the paper after 90 days reported for distribution transformers by UNEP (2002), section 9.4.4. The test after 90 days in service decides the reclassification.

Worked example

Three units from the tool's own test cases, assessed on 26 September 2026:

Unit Input Stockholm EU USA
Transformer in service mineral oil, 350 mg/kg by IEC 61619, 800 L S3: priority (iii) E3: PCBs 0.005 to 0.05 %, above 5 dm³; the 31 December 2025 date of Regulation 2019/1021 is shown as overdue U5: PCB-Contaminated Electrical Equipment
Askarel transformer 600 000 mg/kg, 1 200 L S1: priority (i) E5: PCBs above 0.05 %, inventory equipment U6: PCB Transformer; quarterly inspection, annual with containment for 100 % of the liquid
Retrofill candidate transformer, 400 mg/kg, 900 L, good condition retrofill allowed retrofill allowed retrofill allowed

For the retrofill candidate the tool expects about 40 mg/kg after one cycle (10 % of 400), which is below the 50 mg/kg line of all three texts. The reclassification still depends on the test after 90 days in service.

The first row shows why the EU profile needs both dates. For a unit between 0.005 % and 0.05 %, the Directive lets it run to the end of its useful life, while the Regulation sets removal from use by 31 December 2025 "without prejudice to" the Directive. The tool shows both and leaves the choice to the national competent authority.

Free tools: scope and conditions of use

Retrofill candidates: Ester Retrofill and Fire Risk: Ester Retrofill and Fire Risk. Several transformers and several laboratories? RONIN reads the reports you already receive.